Library prep · the biochemistry underneath the liquid handling

Every transfer is a molecule doing a job.

You already know the verbs on the deck — aspirate, dispense, eject tip. This primer is about the nouns: what each reagent is actually doing to the DNA in the well, why the volume and ratio matter, and why the order of the steps can't be shuffled. It's mapped onto the library prep your workflows already run.

The one idea underneath all of it: every liquid step is a molecule doing a specific job, and the protocol is just those jobs in an order that can't be shuffled. When you watched transfers and tip ejects for fun, you were watching the verbs. The biochemistry is the nouns.

POLYMERASE builds · LIGASE seals · KINASE phosphorylates · BEADS size-select · PROBES capture by pairing

PART 1 — THE PIPELINEEight steps, in the only order that works

Tap a step to see what the molecule does, why it has to happen exactly there, what breaks if you skip it — and what that step looks like from the deck, in the transfers you'd write or simulate. Work through all eight and the “Next step” button will walk you down the chain.

What happens

Why it matters

If you skip or shuffle it

On the deck — the verb you see

PART 2 — HANDS-ONThe SPRI lab: one slider, one size cutoff

SPRI cleanup is the step that happens between almost every other step, and its whole behaviour is set by one number: the ratio of bead buffer to sample. Drag it and watch which fragments survive. This is the “ratio matters” step, made visible.

0.8× — e.g. 80 µL beads into 100 µL sample

More buffer → more PEG crowding the solution → DNA precipitates onto the beads at smaller sizes. Less buffer → only the big fragments come down, and the small ones wash away.

Effective cutoff: ~210 bp — fragments at or above it are kept; below it, they're lost in the wash.

That's how adapter dimers (~120 bp of pure junk — adapter ligated to adapter, no insert) get removed: pick a ratio whose cutoff sits above the dimer and below your library. It's also why cleanup can't be skipped between steps: leftover ligase or free adapters would poison the next reaction.

Kept on the beadsWashed away

Bar height ∝ fragment length. The 120 bp bar is the adapter dimer — the thing you're usually trying to throw away without throwing away your library.

PART 3 — HANDS-ONThe PCR lab: amplification is not free

PCR is how a library gets enough copies to sequence — and it's the step with the honest caveat for oncology. Drag the cycle count and watch two costs grow with it: duplicate reads and GC bias.

10 cycles

Every cycle, primers matching the adapter sequences copy each ligated fragment — which is why only successfully ligated fragments amplify. Unligated DNA has no primer sites and stays invisible. The same primers also carry the sample indices, so this is where multiplexing is added: many samples, one run, told apart by barcode.

More cycles = more material from less input. But copies of copies aren't new information — and fragments don't copy equally.

×1,024
Copies per starting fragment (ideal 2ⁿ)
~9%
Reads that are PCR duplicates
1.2×
GC-balanced vs GC-rich yield gap

Duplicate fraction

Relative yield by fragment type

GC-balanced fragments amplify happily; GC-rich ones (stuck-together, hard to melt apart) lag further behind every cycle. In oncology this is not academic: a variant in a GC-rich exon can be systematically under-counted, and duplicates inflate apparent depth without adding evidence — which is why variant calling marks duplicates and thinks about bias instead of trusting raw read counts.

PART 4 — TRY ITThe order challenge

The protocol is “jobs in an order that can't be shuffled.” Prove it: tap the steps below in the order they have to happen. Capture is the oncology extra — it slots in after amplification, before QC.

PART 5 — CHECK YOURSELFSix questions, all “why”

No volumes, no temperatures — those live in the method file. These are the questions that decide whether a protocol means something. Score: 0 / 6

REFERENCEThe nouns, on one page

The cast of molecules and what each one is for. If you remember nothing else, remember this table — every well in every run contains some subset of it.

Molecule / toolIts one jobWhere it appears
PolymeraseBuilds DNA — fills gaps, copies strands, adds the A-tailEnd repair · A-tailing · PCR
ExonucleaseChews DNA back from an end, removing 3′ overhangsEnd repair
Kinase (PNK)Adds the missing 5′ phosphate ligation requiresEnd repair
LigaseSeals nicks — joins fragment to adapter, backbone to backboneAdapter ligation
AdaptersKnown synthetic DNA: flow-cell grip, sample barcode, primer sitesLigation → everything downstream
SPRI beadsMagnetic beads in PEG/salt; precipitate DNA by size, set by ratioEvery cleanup between steps
Indexed primersCopy only adapter-ligated fragments; stamp the sample barcodeAmplification
Biotinylated probesShort DNA matching genes of interest; pair with their targetsCapture (panels)
Streptavidin beadsGrab biotin — one of the strongest non-covalent bonds in biologyCapture pull-down
Qubit dyeFluoresces only on double-stranded DNA — counts library, not junkQC before loading

Where to go deeper: SPRI sizing and PCR bias are the two steps where a small number (a ratio, a cycle count) quietly decides data quality — and both have a hands-on lab above. In oncology the stakes compound: capture decides which genes get depth, and PCR bias decides how much you can trust the depth you got.