PART 1 — THE PIPELINEEight steps, in the only order that works
Tap a step to see what the molecule does, why it has to happen exactly there, what breaks if you skip it — and what that step looks like from the deck, in the transfers you'd write or simulate. Work through all eight and the “Next step” button will walk you down the chain.
What happens
Why it matters
If you skip or shuffle it
On the deck — the verb you see
PART 2 — HANDS-ONThe SPRI lab: one slider, one size cutoff
SPRI cleanup is the step that happens between almost every other step, and its whole behaviour is set by one number: the ratio of bead buffer to sample. Drag it and watch which fragments survive. This is the “ratio matters” step, made visible.
More buffer → more PEG crowding the solution → DNA precipitates onto the beads at smaller sizes. Less buffer → only the big fragments come down, and the small ones wash away.
Effective cutoff: ~210 bp — fragments at or above it are kept; below it, they're lost in the wash.
That's how adapter dimers (~120 bp of pure junk — adapter ligated to adapter, no insert) get removed: pick a ratio whose cutoff sits above the dimer and below your library. It's also why cleanup can't be skipped between steps: leftover ligase or free adapters would poison the next reaction.
Bar height ∝ fragment length. The 120 bp bar is the adapter dimer — the thing you're usually trying to throw away without throwing away your library.
PART 3 — HANDS-ONThe PCR lab: amplification is not free
PCR is how a library gets enough copies to sequence — and it's the step with the honest caveat for oncology. Drag the cycle count and watch two costs grow with it: duplicate reads and GC bias.
Every cycle, primers matching the adapter sequences copy each ligated fragment — which is why only successfully ligated fragments amplify. Unligated DNA has no primer sites and stays invisible. The same primers also carry the sample indices, so this is where multiplexing is added: many samples, one run, told apart by barcode.
More cycles = more material from less input. But copies of copies aren't new information — and fragments don't copy equally.
Duplicate fraction
Relative yield by fragment type
GC-balanced fragments amplify happily; GC-rich ones (stuck-together, hard to melt apart) lag further behind every cycle. In oncology this is not academic: a variant in a GC-rich exon can be systematically under-counted, and duplicates inflate apparent depth without adding evidence — which is why variant calling marks duplicates and thinks about bias instead of trusting raw read counts.
PART 4 — TRY ITThe order challenge
The protocol is “jobs in an order that can't be shuffled.” Prove it: tap the steps below in the order they have to happen. Capture is the oncology extra — it slots in after amplification, before QC.
PART 5 — CHECK YOURSELFSix questions, all “why”
No volumes, no temperatures — those live in the method file. These are the questions that decide whether a protocol means something. Score: 0 / 6
REFERENCEThe nouns, on one page
The cast of molecules and what each one is for. If you remember nothing else, remember this table — every well in every run contains some subset of it.
| Molecule / tool | Its one job | Where it appears |
|---|---|---|
| Polymerase | Builds DNA — fills gaps, copies strands, adds the A-tail | End repair · A-tailing · PCR |
| Exonuclease | Chews DNA back from an end, removing 3′ overhangs | End repair |
| Kinase (PNK) | Adds the missing 5′ phosphate ligation requires | End repair |
| Ligase | Seals nicks — joins fragment to adapter, backbone to backbone | Adapter ligation |
| Adapters | Known synthetic DNA: flow-cell grip, sample barcode, primer sites | Ligation → everything downstream |
| SPRI beads | Magnetic beads in PEG/salt; precipitate DNA by size, set by ratio | Every cleanup between steps |
| Indexed primers | Copy only adapter-ligated fragments; stamp the sample barcode | Amplification |
| Biotinylated probes | Short DNA matching genes of interest; pair with their targets | Capture (panels) |
| Streptavidin beads | Grab biotin — one of the strongest non-covalent bonds in biology | Capture pull-down |
| Qubit dye | Fluoresces only on double-stranded DNA — counts library, not junk | QC before loading |
Where to go deeper: SPRI sizing and PCR bias are the two steps where a small number (a ratio, a cycle count) quietly decides data quality — and both have a hands-on lab above. In oncology the stakes compound: capture decides which genes get depth, and PCR bias decides how much you can trust the depth you got.